100 A ATS panel supplying fire-fighting pumps. Two inputs and one load, built on LOVATO BF110 contactors. Controlled by БУАВР.КИ.220Incoming and distribution unit with a 115 A ATS, two mains inputs and one load, built on БУАВР1.220 and Moeller DILM115 contactorsIncoming and distribution unit with a 115 A ATS, two mains inputs and one load, built on БУАВР1.220 and Moeller DILM115 contactorsIncoming and distribution unit with a 115 A ATS, two mains inputs and one load, built on БУАВР1.220 and Moeller DILM115 contactors1250 A ATS panel on Socomec ATyS 3e motorised changeover switches, with two mains inputs and a diesel-generator standby input, two equal groups of category I loads, and a bus-section breaker built on a Terasaki TemBreak2 XS1250CE. The ATS control is built on БУАВР.С.220.220 and two БУАВР.ЭА.220.220.12/24 units.ATS panel controlled by БУАВРATS panel controlled by БУАВРATS panel controlled by БУАВР50 A ATS panel on EATON contactors, with two mains inputs and a diesel-generator standby input. The ATS control is built on БУАВР.С.220 and БУАВР.ЭА.220.12/24.250 A contactor-based ATS panel with two mains inputs and a diesel-generator standby input, two equal groups of category I loads and two bus-section breakers. The ATS control is built on БУАВР.2С.220 and two БУАВР.ЭА.220.12/24 units.ATS panel controlled by БУАВРATS panel controlled by БУАВРATS panel on LBA-32 breakers rated 3150 A, with two inputs and one load. The ATS control is built on БУАВР.К.220.220.ATS panel on LBA-32 breakers rated 3150 A, with two inputs and one load. The ATS control is built on БУАВР.К.220.220.ATS panel on LBA-32 breakers rated 3150 A, with two inputs and one load. The ATS control is built on БУАВР.К.220.220.ATS panel on ВА55-43 breakers rated 1600 A, with two inputs and two loads and a bus-section breaker. The ATS control is built on БУАВР.С.220.220. Photograph of the bus-section breaker cubicle.180 A incoming and distribution cabinet with a 3-input ATS — 2 mains and 1 from the generator set — and a bypass supply circuit. Controlled by БУАВР1.220. The power switching devices are Lovato 11 В180-00 contactors145 A ATS panel with 2 mains inputs and one load, controlled by БУАВР1.220. The power switching devices are Lovato 11BF 145-00 contactors.160 A ATS panel with 2 mains inputs and one load, controlled by БУАВР1.220. The power switching device is a Socomec ATyS 3s motorised transfer switch.400 A ATS cabinet with a mains main input, a diesel-generator standby input and one load. The generator set and the Socomec ATyS 3e motorised transfer switch are controlled by БУАВР.ЭА.220.12/24400 A ATS cabinet with a mains main input, a diesel-generator standby input and one load. The generator set and the Socomec ATyS 3e motorised transfer switch are controlled by БУАВР.ЭА.220.12/24400 A ATS cabinet with a mains main input, a diesel-generator standby input and one load. The generator set and the Socomec ATyS 3e motorised transfer switch are controlled by БУАВР.ЭА.220.12/2450 A ATS cabinet with 2 mains inputs and one load, built on БУАВР1.220 and Lovato BF50 contactors50 A ATS cabinet with 2 mains inputs and one load, built on БУАВР1.220 and Lovato BF50 contactors50 A ATS cabinet with 2 mains inputs and one load, built on БУАВР1.220 and Lovato BF50 contactorsATS panel with 2 inputs and one load, built on БУАВР1.220 and contactorsATS panel controlled by БУАВРATS panel controlled by БУАВРCabinet with three transfer switches, each with two inputs and one load, built on БУАВР.К and contactors.ATS cabinet with two mains inputs, a diesel-generator standby input and one load, built on БУАВР.К, БУАВР.ЭА and four contactors.2000 A ATS panel with two inputs and two loads and a bus-section breaker, built on Terasaki TemPower 2 AR220S withdrawable breakers. Controlled by БУАВР.С.220.220.12/24.Т. Breaker trip events are recorded by РЭУ11М flag relaysATS cabinet with two mains inputs, a diesel-generator standby input and one load, built on БУАВР.К, БУАВР.ЭА and contactors.ATS cabinet with two inputs and two loads, with 2 bus-section breakers, built on БУАВР.2C and contactors.ATS cabinet with two mains inputs, a generator-set standby input and one load, built on БУАВР.К, БУАВР.ЭА and motor-driven circuit breakers.ATS cabinet with two inputs and one load, built on БУАВР.К and contactors.ATS panel controlled by БУАВРATS panel controlled by БУАВРATS cabinet with a mains main input, a diesel-generator standby input and one load, built on БУАВР.ЭА and motor-driven circuit breakersATS panel controlled by БУАВРPart of an ATS panel for a data centre. The ATS control is built on БУАВР.КИ.220.М.Part of an ATS panel for a data centre. The ATS control is built on БУАВР.КИ.220.М; the control-power transfer uses the РН1 voltage relay.A four-input ATS panel for a data centre, made up of two identical transfer switches. Each has its own mains input backed by its own diesel generator. The power switching devices are Eaton IZMX 16 breakers rated 1000 A. The ATS control is built on БУАВР.КИ.220.М; the control-power transfer uses the РН1 voltage relay.ATS panel on LOVATO contactors, controlled by БУАВР.КИ with the КЗА battery charge controllerPart of an ATS panel for a data centre. The power switching devices are Socomec ATyS S motorised switches. The ATS control is built on БУАВР.КИ.220.М.Part of an ATS panel for a data centre. One cubicle holds six 63 A transfer switches. The power switching devices are Socomec ATyS S motorised switches rated 63 A. The ATS control is built on БУАВР.КИ.220.М.Part of an ATS panel for a data centre. The power switching devices are Socomec ATyS S motorised switches. The ATS control is built on БУАВР.КИ.220.М.ATS panel controlled by БУАВР1600 A ATS panel built on ABB Emax breakers, with two inputs and two loads and a bus-section breaker. Controlled by БУАВР.С.220.220.Т. 1600 A ATS panel built on ABB Emax breakers, with two inputs and two loads and a bus-section breaker. Controlled by БУАВР.С.220.220.Т. 1600 A ATS panel built on ABB Emax breakers, with two inputs and two loads and a bus-section breaker. Controlled by БУАВР.С.220.220.Т.
Cannot find a product, or have a question about applying one?Ask on the forum →
Need a hand?
Ask on the forum — or read the detailed write-ups in the wiki.